  "title": "Volume sweep imaging lung teleultrasound for detection of COVID-19 in Peru: a multicentre pilot study",
  "authors": "Marini et al.",
  "year": 2022,
  "license": "CC BY-NC 4.0",
  "licenseUrl": "https://creativecommons.org/licenses/by-nc/4.0/",
  "url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC9534786/",
  "originalFilename": "bmjopen-2022-061332supp004.mp4",
  "sourceSha256": "7e1565e32f6c313548caa70db6230d1f1685ed1432458866f67d6975385f2a7b",
  "sourceDuration": 64.4,
  "sourceResolution": [
    1024,
    768
  ],
  "patientAgeYears": 7,
  "sourceContext": "Figure 4 A–B: normal sagittal VSI sweep in an asymptomatic seven-year-old.",
  "displayInterval": [
    16,
    25.5
  ],
  "displayFrames": 96,
  "fps": 10,
  "modifications": "Continuous excerpt; screen furniture outside acquisition sector masked to black; focused 4:3 crop removes deep/peripheral margins. Lossless display atlas. No interpolation, repeated frames, joined clips, recolouring or generated motion.",
  "limitations": "Pediatric source. Adult model is an independent illustrative controller, not patient registration. Manual teaching contours approximate visible structures and are not clinically validated.",
  "annotationLicense": "CC BY-NC 4.0",
  "shadowAnnotations": {
    "version": "0.22.1",
    "frames": 96,
    "method": "Manual rib landmarks constrain local dark-band and edge searches on blurred grayscale source frames. Spatial smoothing and short temporal medians stabilise edges. Rounded display curves share geometry with hit targets; deep fill and open side strokes fade to transparent.",
    "generator": "tools/refine-rib-shadows.py",
    "clinicalValidation": false
  },
  "surfaceAnnotations": {
    "version": "radiovista-ribs-review-2",
    "method": "Each original frame independently fitted within a maximum three-native-pixel corridor around the reviewed source contours. Strong smoothness constraint and a quadratic correction suppress speckle chasing. Outer endpoints trimmed; only the central pleural section retained. Display uses fine centerlines with separate wider hit regions.",
    "generator": "research/ultrasound-ribs-review-2026-10-30/refine.py",
    "limitations": "Approximate teaching annotations, not clinically validated segmentation. No extension through acoustic shadows.",
    "sourcePixelsChanged": false
  },
  "releaseStatus": "PUBLICATION_REQUESTED_BY_SITE_OWNER",
  "commercialPublicationCleared": false,
  "commercialPublicationRequirement": "Additional permission from rightsholder or a commercially licensed replacement.",
  "localReviewChanges": [
    "Frame-specific surface refinement constrained to the original reviewed corridor",
    "Shorter visible rib surface sections",
    "Only the clearer central pleural window retained",
    "Fine centerlines with separate wider hit targets",
    "Source video, atlas pages and shadow contours unchanged"
  ],
  "publicationAuthorization": {
    "date": "2026-10-30",
    "basis": "Site owner explicitly instructed website publication after being informed of CC BY-NC 4.0.",